Relative humidity is the amount of water vapor in air compared with the maximum amount of water vapor possible at the same temperature, expressed as a percentage. More precisely, it compares the actual water vapor pressure with the saturation vapor pressure at a particular temperature.
Relative humidity (RH) is one of the most familiar measures of atmospheric moisture because it appears in weather reports, forecasts, and indoor climate measurements. However, relative humidity does not directly tell how much water vapor is actually in the air. Because the saturation vapor pressure of water increases rapidly with temperature, relative humidity depends on both the amount of water vapor and the air temperature.
For example, if air contains the same amount of water vapor throughout the day, its relative humidity generally decreases as the temperature rises and increases as the temperature falls. If the air cools sufficiently, relative humidity reaches 100%, the air becomes saturated, and condensation may occur.
Key Takeaways: Relative Humidity
- Relative humidity (RH) compares the actual water vapor pressure of air with its saturation vapor pressure at the same temperature.
- Relative humidity is expressed as a percentage from approximately 0% to 100% under ordinary atmospheric conditions.
- Temperature strongly affects relative humidity because warm air has a much higher saturation vapor pressure than cold air.
- Relative humidity can change even when the actual amount of water vapor in the air does not change.
- A hygrometer measures humidity, while a psychrometer determines humidity using wet-bulb and dry-bulb temperatures.
- Dew point is often a better indicator of the actual moisture content of air because it is much less directly affected by changes in air temperature.
- Relative humidity affects weather, evaporation, human comfort, agriculture, fire behavior, buildings, and many biological processes.
Why Relative Humidity Is Important
Relative humidity affects the rate at which water evaporates and condenses. This makes it important in meteorology, biology, agriculture, engineering, manufacturing, and everyday life.
In weather, relative humidity helps describe atmospheric moisture and indicates how close air is to saturation. High relative humidity favors the formation of dew, fog, and clouds when additional cooling occurs, although high relative humidity alone does not guarantee precipitation.
Relative humidity also affects evaporative cooling. Sweat cools the human body primarily when it evaporates. When relative humidity is high, evaporation occurs less readily, reducing the effectiveness of sweating and making hot conditions feel more uncomfortable. When humidity is low, evaporation occurs more readily.
Indoor humidity affects comfort as well as materials. Very dry air encourages evaporation and can dry wood, paper, skin, and other materials. Persistently high humidity promotes condensation and can favor mold growth and deterioration of some materials.
Relative humidity is also important in:
- Agriculture: Plant transpiration, irrigation requirements, crop drying, and fungal diseases depend partly on humidity.
- Wildfire behavior: Low relative humidity dries vegetation and other fuels, increasing their ability to burn.
- Weather forecasting: Humidity helps meteorologists evaluate fog, clouds, precipitation, and atmospheric stability.
- Museums and archives: Changes in humidity can damage paper, wood, paintings, textiles, and other sensitive materials.
- Manufacturing: Electronics, pharmaceuticals, food processing, printing, and many other industries require humidity control.
- Animal and plant care: Humidity influences water loss, temperature regulation, and the environments required by many organisms.
What Is Relative Humidity?
Relative humidity describes how close air is to saturation with water vapor at its current temperature.
The most precise way of defining relative humidity uses vapor pressure:
Relative humidity = (actual vapor pressure / saturation vapor pressure) × 100%
or:
RH = (e / eₛ) × 100%
where:
- RH = relative humidity
- e = actual water vapor pressure
- eₛ = saturation vapor pressure at the same temperature
At 100% relative humidity, the actual vapor pressure equals the saturation vapor pressure.
At 50% relative humidity, the actual vapor pressure is half the saturation vapor pressure at that temperature.
Does Warm Air Really “Hold More Water”?
It is common to say that “warm air can hold more water than cold air.” This is a useful shortcut, but it is not a precise description of the physics.
Air does not act like a container with a fixed moisture capacity. Instead, the saturation vapor pressure of water increases strongly with temperature. At higher temperatures, a larger concentration of water vapor can coexist with liquid water before equilibrium favors condensation.
So, it is more accurate to say:
The saturation vapor pressure of water is higher at higher temperatures.
This temperature dependence explains much of the behavior of relative humidity.
How Temperature Changes Relative Humidity
Suppose a parcel of air contains a fixed amount of water vapor and neither gains nor loses moisture.
If the air warms, its saturation vapor pressure increases. The actual vapor pressure remains approximately the same, so:
Relative humidity decreases.
If the air cools, saturation vapor pressure decreases while actual vapor pressure initially remains approximately the same, so:
Relative humidity increases.
Eventually, cooling may bring the air to 100% relative humidity. Further cooling ordinarily results in condensation.
This explains why relative humidity often reaches its highest value around the coolest part of the day and its lowest value during the warmer afternoon, even without a major change in the amount of atmospheric water vapor.
Relative Humidity and Saturation
Air is saturated when its water vapor pressure equals the saturation vapor pressure at that temperature.
At saturation:
RH = 100%
However, 100% relative humidity does not necessarily mean it is raining. Saturated air may produce dew, frost, fog, or clouds if appropriate surfaces or condensation nuclei and other conditions are present.
It is also possible for air to become temporarily supersaturated, meaning its water vapor pressure exceeds the equilibrium saturation vapor pressure. Relative humidity can therefore exceed 100% under special atmospheric or laboratory conditions, although this situation is generally unstable.
How to Calculate Relative Humidity
If the actual vapor pressure and saturation vapor pressure are known, calculating relative humidity is straightforward:
RH = (e / eₛ) × 100%
Example 1: Calculate Relative Humidity From Vapor Pressure
Suppose the actual water vapor pressure is 1.40 kPa and the saturation vapor pressure at the air temperature is 2.34 kPa.
RH = (1.40 kPa / 2.34 kPa) × 100%
RH = 59.8%
The relative humidity is approximately:
RH = 60%
Notice that the units cancel. Relative humidity is a dimensionless ratio expressed as a percentage.
Calculating Relative Humidity From Temperature and Dew Point
If air temperature and dew point are known, relative humidity can be calculated from their saturation vapor pressures.
At the dew point, the saturation vapor pressure equals the actual vapor pressure of the air. Therefore:
RH = [eₛ(Td) / eₛ(T)] × 100%
where:
- T = air temperature
- Td = dew-point temperature
- eₛ(T) = saturation vapor pressure at the air temperature
- eₛ(Td) = saturation vapor pressure at the dew point
A useful approximation for saturation vapor pressure over liquid water is:
eₛ(T) = 6.112 exp[17.62T / (243.12 + T)]
where T is in degrees Celsius and eₛ is in hectopascals (hPa).
Example 2: Relative Humidity From Dew Point
Suppose:
Air temperature = 20°C
Dew point = 10°C
The approximate saturation vapor pressures are:
eₛ(20°C) ≈ 23.3 hPa
eₛ(10°C) ≈ 12.3 hPa
So:
RH ≈ (12.3 / 23.3) × 100%
RH ≈ 53%
The relative humidity is approximately 53%.
How Relative Humidity Is Measured
An instrument that measures humidity is called a hygrometer.
Several types of hygrometers exist.
Electronic Hygrometers
Most modern electronic hygrometers use a sensor whose electrical properties change as it absorbs or releases water. Capacitive humidity sensors, for example, detect changes in capacitance caused by atmospheric moisture.
Digital weather stations, thermostats, data loggers, and many household humidity meters use electronic sensors.
Mechanical Hygrometers
Traditional mechanical hygrometers use materials that change dimensions in response to humidity. Human or animal hair was historically used because its length changes slightly with relative humidity.
Chilled-Mirror Hygrometers
A chilled-mirror hygrometer cools a reflective surface until condensation first appears. Measuring this temperature gives the dew point, from which humidity can be determined. Chilled-mirror instruments are particularly useful when accurate dew-point measurements are required.
Psychrometers
A psychrometer consists of two thermometers:
- a dry-bulb thermometer, which measures ordinary air temperature
- a wet-bulb thermometer, whose bulb is covered by a wet wick
Evaporation cools the wet bulb. The difference between the dry-bulb and wet-bulb temperatures reveals information about the amount of water vapor in the air.
How a Psychrometer Measures Relative Humidity
The key to a psychrometer is evaporative cooling.
Water requires energy to change from liquid into vapor. As water evaporates from the wet wick, it absorbs latent heat from the thermometer and surrounding air, cooling the wet-bulb thermometer.
In relatively dry air, evaporation occurs readily. The wet bulb cools substantially below the dry-bulb temperature.
In humid air, evaporation occurs more slowly because the air is already closer to saturation. The temperature difference is smaller.
At or very near 100% relative humidity, little or no net evaporation occurs and:
wet-bulb temperature ≈ dry-bulb temperature
The difference between these temperatures is called the wet-bulb depression:
Wet-bulb depression = dry-bulb temperature − wet-bulb temperature
A large wet-bulb depression indicates relatively dry air.
A small wet-bulb depression indicates relatively humid air.
What Is a Sling Psychrometer?
A sling psychrometer is a psychrometer designed so that its wet-bulb and dry-bulb thermometers can be swung rapidly through the air.
Moving the thermometers provides a steady flow of air across both bulbs. This ventilation increases evaporation from the wet wick and helps the wet-bulb thermometer reach a reproducible equilibrium temperature.
Once the temperatures stabilize, the observer records the dry-bulb and wet-bulb temperatures and uses a psychrometric table, chart, or equation to determine relative humidity.
How to Build a Simple Sling Psychrometer
A simple classroom psychrometer requires:
- Two identical thermometers
- Cotton gauze, muslin, or a small piece of absorbent cloth
- Water
- Rubber bands or thread
- A rigid strip or other holder
- String or a handle that allows the instrument to rotate safely
Procedure
- Place the two thermometers side by side on the holder.
- Leave the bulb of one thermometer uncovered. This is the dry bulb.
- Wrap the bulb of the second thermometer with a small piece of clean absorbent cloth. This is the wet bulb.
- Secure the cloth without covering unnecessary parts of the thermometer.
- Thoroughly wet the cloth with clean water. Distilled water is preferable.
- Move to an open, shaded location away from direct sunlight and strong heat sources.
- Swing the psychrometer through the air for about 30 seconds.
- Stop and quickly read both thermometers.
- Wet the wick again if necessary and repeat.
- Continue until the wet-bulb temperature stops decreasing significantly between measurements.
- Calculate the wet-bulb depression.
- Use a psychrometric table or equation to determine the relative humidity.
For safety, a classroom sling psychrometer should use non-mercury thermometers and a secure holder. Make certain there is ample open space before swinging it.
Psychrometric Table
A psychrometric table is a lookup table that estimates relative humidity using the dry-bulb temperature and the difference between the dry-bulb and wet-bulb temperatures.
It is sometimes informally called a relative humidity table or wet-bulb/dry-bulb table.
Here is a compact educational psychrometric table. Values are approximate and assume ordinary near-sea-level atmospheric pressure (about 1013 hPa). More precise psychrometric calculations account for atmospheric pressure, so values in published tables may differ slightly, particularly at higher elevations.
Approximate Relative Humidity (%)
| Dry-Bulb Temperature | 0°C Depression | 1°C | 2°C | 3°C | 4°C | 5°C | 6°C | 8°C | 10°C |
|---|---|---|---|---|---|---|---|---|---|
| 0°C | 100 | 82 | 65 | 48 | 31 | 15 | — | — | — |
| 10°C | 100 | 88 | 76 | 65 | 54 | 44 | 33 | 14 | — |
| 20°C | 100 | 91 | 82 | 74 | 66 | 58 | 51 | 37 | 24 |
| 30°C | 100 | 93 | 86 | 79 | 73 | 67 | 61 | 49 | 39 |
| 40°C | 100 | 94 | 88 | 82 | 77 | 71 | 66 | 57 | 48 |
A dash indicates a combination for which this simplified table is not useful under ordinary conditions.
How to Use a Psychrometric Table
Suppose a sling psychrometer gives:
Dry-bulb temperature = 20°C
Wet-bulb temperature = 15°C
First calculate the wet-bulb depression:
20°C − 15°C = 5°C
Find the 20°C row and the 5°C depression column.
The table gives approximately:
RH = 58%
So, the relative humidity is about 58%.
A full meteorological psychrometric table contains many more temperatures and wet-bulb depressions than this simplified version.
Relative Humidity vs Other Measures of Humidity
Atmospheric moisture can be described in several ways. These quantities are related, but they are not interchangeable.
| Measure | What It Describes | Typical Units | Strongly Temperature-Dependent? |
|---|---|---|---|
| Relative humidity | Actual vapor pressure compared with saturation vapor pressure | % | Yes |
| Dew point | Temperature at which air becomes saturated when cooled | °C or °F | Not in the same direct way as RH |
| Absolute humidity | Mass of water vapor per volume of air | g/m³ | Depends partly on volume and therefore temperature/pressure |
| Specific humidity | Mass of water vapor per total mass of moist air | g/kg or kg/kg | Much less directly |
| Mixing ratio | Mass of water vapor per mass of dry air | g/kg | Much less directly |
| Vapor pressure | Partial pressure exerted by water vapor | Pa, hPa, or kPa | Represents actual vapor amount more directly |
| Wet-bulb temperature | Equilibrium temperature reached through evaporative cooling | °C or °F | Depends on temperature, moisture, and pressure |
Relative Humidity vs Absolute Humidity
Absolute humidity is the mass of water vapor divided by the volume of air:
Absolute humidity = mass of water vapor / volume of air
It is commonly expressed in grams per cubic meter (g/m³).
Relative humidity does not directly measure this quantity. Instead, it compares the current vapor pressure with saturation vapor pressure.
This distinction explains why two air masses can have the same relative humidity but very different amounts of water vapor.
For example, warm tropical air at 50% RH can contain much more water vapor than cold winter air at 50% RH.
Relative Humidity vs Dew Point
The dew point is the temperature to which air must cool, at approximately constant pressure and water vapor content, to become saturated with respect to liquid water.
When:
air temperature = dew point
the relative humidity is approximately:
RH = 100%
The closer the air temperature is to the dew point, the higher the relative humidity tends to be.
Unlike relative humidity, dew point does not change simply because the air temperature changes, provided the amount of water vapor and pressure remain approximately constant. For this reason, dew point is often more useful for comparing the actual moisture content of different air masses.
Relative Humidity vs Wet-Bulb Temperature
The wet-bulb temperature is the temperature reached by a properly ventilated, wetted thermometer as evaporation cools it toward equilibrium.
The wet-bulb temperature normally falls between the air temperature and dew point:
dew point ≤ wet-bulb temperature ≤ air temperature
When the air is saturated, all three temperatures are equal:
dew point = wet-bulb temperature = air temperature
Wet-bulb temperature is especially important when considering evaporative cooling and heat stress.
Why Relative Humidity Changes During the Day
Relative humidity commonly follows a daily cycle even if the amount of water vapor changes very little.
During the morning, rising temperatures increase saturation vapor pressure, causing relative humidity to fall.
Relative humidity often reaches a minimum near the warmest part of the afternoon.
After sunset, the surface and nearby air cool. Saturation vapor pressure decreases, causing relative humidity to rise. The highest relative humidity often occurs around the coolest part of the night or early morning.
If the temperature reaches the dew point, condensation can produce dew or fog.
This daily cycle demonstrates why relative humidity should always be interpreted together with temperature.
Relative Humidity and the Heat Index
Relative humidity influences how hot weather feels because it affects the evaporation of sweat.
At high temperatures and high relative humidity, sweat evaporates less efficiently. The body therefore has greater difficulty losing heat through evaporation.
The heat index combines air temperature and relative humidity to estimate how hot conditions feel to the human body under specified conditions.
However, relative humidity alone does not determine heat stress. Temperature, wind, sunlight, clothing, activity, acclimatization, and other factors also matter.
Relative Humidity, Clouds, Fog, and Dew
High relative humidity means air is relatively close to saturation, but it does not automatically mean clouds, fog, dew, or rain will form.
Condensation usually requires the air to reach saturation through cooling, addition of water vapor, or another process.
Dew forms when a surface cools enough for nearby air to become saturated and water vapor condenses on the surface.
Fog consists of tiny water droplets or ice crystals suspended near Earth’s surface and often develops when near-surface air becomes saturated.
Clouds commonly form when rising air expands and cools enough to reach saturation.
Thus, relative humidity provides information about how close the atmosphere is to saturation, but other atmospheric processes determine whether visible condensation or precipitation develops.
Common Misconceptions
“50% humidity means half the air is water vapor.”
No. A relative humidity of 50% means the actual water vapor pressure is 50% of the saturation vapor pressure at that temperature. Water vapor still makes up only a relatively small fraction of the atmosphere.
“Relative humidity tells you exactly how much water is in the air.”
No. Relative humidity depends strongly on temperature. Dew point, vapor pressure, specific humidity, or mixing ratio provides more direct information about atmospheric water vapor content.
“Warm air holds more water.”
This familiar statement is an approximation. Air is not a container that becomes “full.” The more precise explanation is that the saturation vapor pressure of water increases with temperature.
“100% relative humidity means it must be raining.”
No. It means the air is saturated with respect to water under the specified conditions. Saturated air may occur without precipitation.
“Relative humidity cannot exceed 100%.”
Usually RH remains at or below 100%, but supersaturated air with RH above 100% can briefly exist. Cloud formation itself often involves small degrees of supersaturation.
“High humidity always means there is more water vapor in the air.”
Not necessarily. Cold air can have a high relative humidity while containing less water vapor than much warmer air with a lower relative humidity.
“The wet-bulb thermometer is colder because the water itself is cold.”
Not necessarily. It becomes cooler primarily because evaporation absorbs energy. This is the same basic process responsible for the cooling effect of sweating.
Frequently Asked Questions
What is relative humidity in simple terms?
Relative humidity describes how close the air is to saturation with water vapor at its current temperature. It is expressed as a percentage.
What does 50% relative humidity mean?
It means the actual water vapor pressure is half the saturation vapor pressure at the current temperature.
What does 100% relative humidity mean?
It means the air is saturated: its actual water vapor pressure equals the saturation vapor pressure at that temperature.
Why does relative humidity decrease when temperature rises?
Higher temperatures have higher saturation vapor pressures. If the actual amount of water vapor remains approximately unchanged while the air warms, the ratio of actual vapor pressure to saturation vapor pressure decreases.
Why does humidity usually rise at night?
Air usually cools at night. As temperature decreases, saturation vapor pressure decreases, so relative humidity rises even if the amount of water vapor remains approximately constant.
What is the difference between humidity and relative humidity?
Humidity is a general term describing water vapor in the atmosphere. Relative humidity is one particular measure of humidity that compares actual vapor pressure with saturation vapor pressure at the same temperature.
What instrument measures relative humidity?
A hygrometer measures humidity. Common types include electronic hygrometers and psychrometers. A sling psychrometer uses wet-bulb and dry-bulb temperatures to determine relative humidity.
What is the difference between dew point and relative humidity?
Relative humidity indicates how close air is to saturation at its current temperature. Dew point is the temperature at which the air would become saturated if cooled without substantially changing its water vapor content.
Which is better, relative humidity or dew point?
It depends on the purpose. Relative humidity is useful for describing proximity to saturation and processes such as evaporation. Dew point is generally more useful for comparing the actual moisture content of different air masses.
Why are wet-bulb and dry-bulb temperatures the same at 100% humidity?
At saturation, there is essentially no net evaporative cooling from the wet bulb under equilibrium conditions. Without significant evaporation, the wet bulb does not cool below the surrounding air temperature.
Can relative humidity be 0%?
In principle, 0% RH corresponds to air containing essentially no water vapor. In Earth’s lower atmosphere, exactly 0% relative humidity is extraordinarily unlikely.
Can relative humidity exceed 100%?
Yes. Air can temporarily become supersaturated, especially in cloud formation and certain laboratory conditions. However, significant supersaturation is usually unstable because excess water vapor tends to condense when suitable nuclei or surfaces are available.
References
- Fanger, P. O. (1970). Thermal Comfort: Analysis and Applications in Environmental Engineering. Danish Technical Press. ISBN 978-87-571-0341-0.
- Himmelblau, David M. (1989). Basic Principles And Calculations In Chemical Engineering. Prentice Hall. ISBN 0-13-066572-X.
- Lide, David (2005). CRC Handbook of Chemistry and Physics (85 ed.). CRC Press. pp. 15–25. ISBN 0-8493-0485-7.
- Wiederhold, Pieter R. (1997). Water Vapor Measurement, Methods and Instrumentation. New York: Marcel Dekker. ISBN 978-0-8247-9319-7.
- Wolkoff, Peder; Kjaergaard, Søren K. (2007). “The dichotomy of relative humidity on indoor air quality”. Environment International. 33 (6): 850–857. doi:10.1016/j.envint.2007.04.004